PlusLib  2.9.0
Software library for tracked ultrasound image acquisition, calibration, and processing.

DeviceDAQVideoSource

This device allow you to use a DAQ USB-FRM13-B grabber to capture and send images from a CameraLink camera.

This device only works in Windows (2023-03-16).

DAQVideoSourceConfigInstallation

You can found the license in: "PlusLib/src/Utilities/DAQVideoSource/README.md"

Device configuration settings

  • attribute.png
    Type = "DAQVideoSource"
    required.png
  • element.png
    DataSources Exactly one DataSource child element is required.
    required.png
    • element.png
      DataSource
      required.png
      • attribute.png
        PortUsImageOrientation
        required.png

Example configuration file PlusDeviceSet_Server_DAQVideoSource.xml

<PlusConfiguration version="2.1">
<DataCollection StartupDelaySec="1.0" >
<DeviceSet
Name="PlusServer: DAQ USB3-FRM13-B Grabber (CameraLink)"
Description="Broadcasting acquired video through PlusServer from a DAQ USB3-FRM13-B Grabber (CameraLink)"
/>
<Device
Id="VideoDevice"
Type="DAQVideoSource"
DataMode="16"
>
<DataSources>
<DataSource Type="Video" Id="Video" PortUsImageOrientation="UF"/>
</DataSources>
<OutputChannels>
<OutputChannel Id="VideoStream" VideoDataSourceId="Video" />
</OutputChannels>
</Device>
</DataCollection>
<CoordinateDefinitions>
<Transform From="Image" To="Reference"
Matrix="
0.5 0 0 0
0 -0.5 0 0
0 0 0.5 0
0 0 0 1" />
</CoordinateDefinitions>
<PlusOpenIGTLinkServer
MaxNumberOfIgtlMessagesToSend="1"
MaxTimeSpentWithProcessingMs="33"
ListeningPort="18944"
SendValidTransformsOnly="true"
OutputChannelId="VideoStream" >
<DefaultClientInfo>
<MessageTypes>
<Message Type="IMAGE" />
</MessageTypes>
<ImageNames>
<Image Name="Image" EmbeddedTransformToFrame="Reference" />
</ImageNames>
</DefaultClientInfo>
</PlusOpenIGTLinkServer>
</PlusConfiguration>